Model | LRS-350-3.3 | LRS-350-4.2 | LRS-350-5 | LRS-350-12 | LRS-350-15 | ||
Output | DC Voltage | 3.3V | 4.2V | 5V | 12V | 15V | 24V |
Rated Current | 60A | 60A | 60A | 29A | 23.2A | 14.6A | |
Current Range | 0 ~ 60A | 0 ~ 60A | 0 ~ 60A | 0 ~ 29A | 0 ~ 23.2A | 0 ~ 14.6A | |
Rated Power | 198W | 252W | 300W | 348W | 348W | 350.4W | |
Ripple&Noise(max.) Note 2 | 150mVp-p | ||||||
Voltage ADJ. Range | 2.97 ~ 3.6V | 3.6 ~ 4.4V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | |
Voltage Tolerance Note.3 |
±4.0%
|
±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | |
Line Regulation Note.4 | ±0.5% | ||||||
Load Regulation Note.5 | ±2.5% | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | |
Setup, Rise Time | 1300ms, 50ms/230VAC 1300ms, 50ms/115AVC at full load | ||||||
Hold UP Time(Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||||
Input | Voltage Rance | 90 ~ 132VAC / 180 ~ 264 VAC by switch 240 ~ 370 VDC (switch on 230VAC) | |||||
Frequency Rance |
47 ~ 63Hz | ||||||
Efficiency(Typ.) | 79.5% | 81% | 83.5% | 85% | 86% | 88% | |
AC Current(Typ.) | 6.8A/115VAC 3.4A/230VAC | ||||||
Inrush current(Typ.) | 60A/115VAC 60A/230VAC | ||||||
Leakage current | <2mA/240VAC | ||||||
Protection | Over Load | 110 ~ 140% rated output power | |||||
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. |
|||||||
Over Voltage | 3.8 ~ 4.45V | 4.6 ~ 5.4V | 5.75 ~ 6.75V | 13.8V ~ 16.2V | 18 ~ 21V | 28.8 ~ 33.6V | |
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. |
|||||||
Over Temperature | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. |
||||||
Function | Fan ON/OFF control(Typ.) | RTH3>=50ºC FAN ON, <=40ºC FAN OFF | |||||
Environment | Working Temp | -25 ~ +70ºC (Refer to "Derating Curve") | |||||
Working Humidity | 20 ~ 90% RH non-condensing | ||||||
Storage Temp., Humidity | -40 ~ +85ºC 10 ~ 95% RH | ||||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | ||||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
Safety | Safety Standards |
IEC/UL 62368-1, BSMI CNS14336-1, BS EN/EN60335-1,EAC TP TC 004,KC K60950-1(for LRS-350-12/24 only),
BIS IS13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS62368.1 approved; Design refer to BS EN/EN62368-1
|
|||||
Withstand Votage |
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
|
||||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25ºC/ 70% RH
|
||||||
EMC Emission |
Compliance to BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only)
|
||||||
EMC Immunity |
Compliance to EAC TP TC 020,KC KN32,KN35(for LRS-350-12/24 only)
|
||||||
Others | MTBF |
327.9K hrs min. MIL-HDBK-217F (25ºC)
|
|||||
DIMENSION |
215*115*30mm (L*W*H)
|
||||||
Packing |
0.76Kg; 15pcs/12.4Kg/0.78CUFT
|
||||||
NOTE | 1. Tolerance: Includes set up tolerance, line regulation and load regulation. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire teminated with a 0.1μ f & 47μ f parallel capacitor. |